Engineered devices and accessories designed specifically for detecting and monitoring air contaminants in industrial and environmental applications; monitoring units available include personal-level styles and large area ambient air style.
Products (35)
35 Products
Filter
  • Particulate Detection Monitors (29)
    Air Monitoring Systems (5)
    Air Sampling Pumps (1)
    Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
  • Show all
: 16.67 L/min. : 16 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional) 8 User-Defined Analog Outputs (0 -1 or 0 -5 VDC). : -22°F to +113°F. : -30°C to +45°C.
: 2.2 L/min. : 25% of the reference method (for concentrations greater than 0.2 mg/m3)
Minimum dust loading: 0.1 mg (to achieve specification)
Maximum dust loading: 4.0 mg (to achieve specification)
Accuracy only valid within operating temperature of -4° to 104° F (-20° to +40° C) and with a relative humidity from 0% to 100%
:
  • NIOSH approval number TC-74CPDM-01
  • Certified intrinsically safe by the Mine Safety Health Administration (MSHA) (19-A040002-0)
  • EN61326-1:2005 - Pending
  • FCC Part 15 subpart B - Pending
  • UN T1-T8 (shipment of lithium ion batteries)
  • The PDM3700 Charger complies with the ANSI/UL 1012 standard for power units other than Class 2, 7th Edition (4/29/05) - Pending
.
: 30 minutes.
: 13.67 L/min. : 4 Averaged Analog Inputs (0 to 5 VDC) with User-defined Conversion to Engineering Units. : Tapered Element Oscillating Microbalance (TEOM) Technology. : 46.4°F to 77°F
: 16.67 L/min. : 6 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional), 8 User-defined Analog Outputs (0 to 1 or 0 to 5 VDC). : -22°F to +122°F. : -30°C to +50°C.
: Continuous Emissions Monitoring System. : Meets U.S. EPA performance specifications : Continuous Emissions Monitoring System. : 0 to 10,000ppm.
: -22°F to +122°F. : -30°C to +50°C. : 0.2 A (at 120 VAC); 1.1 A (at 240 VAC) : USEPA PM-2.5 Equivalent sampler: EQPS-0509-177
This product has been discontinued; this includes the discontinuation of spare/replacement parts and all service and support.
: Complete Enclosure for TEOM Series 1405. : 6-way outlet strip with power surge protector (Quantity 1). : 180 lb. (without instrument) : 82 kg (without instrument).
: Omni FTIR Multi Gas CEMS. : Omni FTIR Multi Gas CEMS. : 230 V.
: -14°F to +122°F. : -40°C to +50°C. : Direct software support for single-point and multi-point audit/calibrations of the volumetric flow. : CE: EN550011 Group 1, Class B (Emissions); EN55082-1 (Immunity); EN61010-1 (Safety)ETL: UL and CSA Equivalent approval.
: -40°F to +122°F. : -40°C to +50°C. : Direct software support for single-point and multi-point audit/calibrations of the volumetric flow. : CE: EN550011 Group 1, Class B (Emissions); EN55082-1 (Immunity); EN61010-1 (Safety)ETL: UL and CSA Equivalent approval.
: 1 to 3.5 L/min. : 14°F to 122°F. : 10°C to 50°C. : ±0.5% of reading or ±0.0015mg/m3, whichever is larger, for 10-second averaging time
: 12 L/min. : 4 Averaged Analog Inputs (0 to 5 VDC) with User-defined Conversion to Engineering Units. : Tapered Element Oscillating Microbalance (TEOM) Technology. : 46.4°F to 77°F
: 14 to 20 L/min. : 16 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional) 8 User-Defined Analog Outputs (0 -1 or 0 -5 VDC). : 0.02% (24 hr.) : 39.2°F to 122°F
Collect gases and particulate matter for laboratory analysis with the Thermo Scientific™ ChemComb 3500 Speciation Collection Cartridge. This flexible sampling device is made up of a single cartridge, which contains a well-characterized inlet with a PM-2.
Results per page15 30 60